202110

光伏组件PID问题对光伏发电量的影响
发布人:网站管理员 发布时间:2021/10/18 点击次数:98次
  

光伏组件PID问题对光伏发电量的影响
杜永亮
(中节能(平原) 太阳能科技有限公司,山东 德州 253100)
摘要: 以平原大棚电站为项目背景,电站在投入使用3 a多后,陆续出现组件PID 现象。统计发现,组件存在PID 现
象共计59 条支路。经过测量实际电压电流发现问题,修复组件,使输出电流值恢复,光伏发电达到对发电量的要求。
关键词: PID 现象;光伏发电;发电量
中图分类号: TM914     文献标识码: A     文章编号: 2095-0802-(2021)10-0034-03
Influence of Photovoltaic Module PID Problem on Photovoltaic Power Generating Capacity
DU Yongliang
(CECEP (Pingyuan) Solar Energy Technology Co., Ltd., Dezhou 253100, Shandong, China)
Abstract: Taking the greenhouse power station in Pingyuan as the project background, after the power station has been put into
use for more than 3 years, the module PID phenomenon has appeared one after another. Statistics show that there are 59 branches
with PID phenomenon. After measuring the actual voltage and current, the problem was found, the module was repaired to restore
the output current value, and the photovoltaic power generation met the requirements for power generation.

Key words: PID phenomenon; photovoltaic power generation; generating capacity